-40%

Shalya Easy Electro surgical Generator Bipolar Monopolar Unit Electro Cautery fd

$ 855.35

Availability: 100 in stock

Description

We sell only Quality Equipment
We are professional company deals in Healthcare equipment for the last 20 years.
Shipment through DHL Delivery within 4-7 working days
Electro Surgical Generator
Description
Model
Shalya Easy
Electrosurgical Generator 250W Monopolar + Bipolar, 3 Prog.
2 Bipolar Modes. Max Power – 60W
3 Cut Modes. Max Power - 250W
3 Coag Modes. Max Power – 100W
6 SENSE Technology ESU
PREM Patient Return Electrode Monitoring.
Randomized SPRAY Coag
Bipolar Cut: in Macro Bip
BiCoag Alarm (Optional)
User Programmable : THREE Surgical Programs
Self Diagnosis
Argon Beam Coagulator up-gradable
Applications
• Gynecology • Urology( TURP ) • Laproscopic Surgeries • Endoscopy ( ERCP ) • Oncosurgery • Heart & Chest surgery, CABG •Neurosurgery, Spine • Arthroscopy • All other general surgical procedures.
Features of Shalya Easy
6 SENSE Technology : Maintain set power over wider range of tissue by Tissue Feedback Technology.
PREM : Patient Return Electrode Monitoring - Safety against the Patient Return Electrode site burns.
Randomized SPRAY Coag : Homogeneous, superficial, faster Coagulation over larger area.
Self Diagnosis : Ensure the ESU with accessories are safe for functioning & display Error Codes if any.
Bipolar Cut : Macro mode can be used for bipolar cutting with hooks and other cutting devices.
Upgradability : Argon Beam Coagulation, Ultrasonic Aspirator, Smoke Evacuator, Suction Irrigation module.
User Programmable : TEN Surgical Programs help in setting the system after power ON.
BiCoag Alarm : Audio feedback after completion of Bipolar Coag, reduces charring and sticking.
Soft / Desiccate Coag : Faster cutting with coagulation for thicker tissues & soft coagulation.
Remote Power Settings : Change mode and power from sterile field by normal Handswitch Pencil.
Foot Switches / Pedals : Explosion Proof (Fire Resistance) and Water Proof Foot Pedals
Time Out Function (Optional) : Automatically stops the HF output if prolon
g unintended activation.
Surgical Applications
:
Useful for wide range of surgical application as : Plastic, Neuro, ENT, Spine,
Opthal, Laparo Surgery, Endo, GI, Ortho, Open & General Surgery, Onco, Gynecology, Hernia,
GI Endocut, Papillotomy, Polypectomy, Under Water, Urology, Gynec TCRE, Hysteroscopy, Thoracotomy,
Thoracic and Cardiac Surgery. Unit is suitable for all kind of Open, Endoscopic, Laparoscopic and Minimally Invasive Surgery
MONOPOLAR AUTOCUT :
Pure Sine wave 390 kHz
Sp Cut- Programmable Pulse or continues output,
250 W at 300 ?, CF 1.5
Pure - Continues output, 250 W at 300 ?, CF 1.5
Blend - Bursts repeating at 29 kHz 55% ON cycle,
150 W at 300 ?, CF 2.5
MONOPOLAR COAG :
Damped Sine wave 460 kHz
Soft - Repetition Frequency 62 kHz, 100 W at 500 ?, CF 5.0
Fulgurate - Repetition Frequency 34 kHz, 100 W at 500 ?, CF 7.0
Spray - Randomized Repetition Frequency 34 kHz < f < 50 kHz,
100 W at 500 ?, CF 8.0
BIPOLAR :
Pure Sine wave 390 kHz
Micro - Lower output voltage, 60 W at 100 ?, CF 1.5
Macro - Higher output voltage, 60 W at 100 ?, CF 1.5
LEAKAGE CURRENTS
• RF leakage current • Monopolar : < 150 mA rms
• Bipolar : < 60 mA rms
• Low Frequency leakage currents
• Normal polarity, intact ground : < 10 ?A
• Normal polarity, ground open : < 50 ?A
PREM SYSTEM
Measuring Frequency : 85 kHz ± 10 kHz.
Measuring current : < 10 ?A
Acceptable Resistance Range upto 40%
Dual Area PREM Patient Return Electrode : 5-135 ? (Adaptive)
Single Area Patient Return Electrode : < 10 ?
FEEDBACK SYSTEM
• 3 Microprocessor Controlled 6SENSE Technology with sampling rate above 4000 sense/second
• Maximum output power deviation < 15% or 5 watts,whichever is greater at any setting with PER-98
INPUT POWER
Operating Voltage : 90-270 Volt AC,
Max. Power input : 1000 VA, Fuse : 4 A
DIMENSIONS
L x W x H in cm - 38.0 x 30.5 x 11.5, Weight in kg < 5.0
DESIGN STANDARD
Classification according to the EC- Directive 93/ 42/ EEC: Class IIb
General Safety Standards: IEC 60601-1-1, IEC 60601-2-2 EMI/EMC Compatibility Standard: IEC 60601-1-2
IS Safety Standard: IS 7583
Supplied with Standard accessories:
1) E214: Patient Plate return electrode with Cable, Rubber :1No.
2) E201: Footswitch Single Paddle: 1No.
3) E202: Footswitch Double Paddle:1No.
4) E242: Footswitching chuck Handle :1No.
5) E251: Monopolar Handswitching pencil (Reusable):1No.
6) E267: Bipolar Forceps, straight, 20cm, 1mm tip:1No.
7) E121: Cord for Bipolar Forcep: 1No.
8) E141: Universal Adaptor:1No.
9) E 151, E153 & E154: Set of Electrode:1No.
(Needle Electrode-5cm, Ball Electrode,-5cm, Angled Blade Electrode-5cm)
Buyer please note only mentioned accessories will be supplied with the unit. In photograph there is so many other accessories which will not supplied with the unit.
Order safe item from us:
The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for
REFERENCE:
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item.
Thank you
jy